| Installation Diameter | 6, 8, 10 and 12 inch (150, 200, 250 and 300 mm) |
| Pulled-in-Place Piping (PIPP) | |
| Materials | Composite of woven textile jacket with resin and polymeric membrane |
| Cured-in-Place Piping (CIPP) | |
| Meets ASTM F 1743 | |
| Up to 500 feet (150 meters) between access pits. | |
| > 120 | |
| Density | 1,15 g/cm³ (ASTM D792) |
ASTM D790 |
> 31 MPa (4 500 psi) |
> 45 MPa (6500 psi) |
|
ASTM D790 |
> 1 724 MPa (250 000 psi) |
> 2 000 MPa (290000 psi) |
|
ASTM D638 |
> 21 MPa (3 000 psi) |
> 60 MPa (8700 psi) |